Basic Info.
Usage
High Intensity Discharge, High Pressure Sodium, UV Lamp Dimming
Matched Tube
Mercury, Metal Halide Lamp, Gallium Lamp or Others
Power Factor Compensation
Active
Certification
CE, E-Mark, ISO9001:2000, RoHS, CCC, FCC, VDE, AAA Certificate
Digital Input
Standard Configuration 3 Digital Input
Digital Output
Standard Configuration 3 Digital Output
Analog Output
2 Route 0.0~10.0V Voltage Output Signal
Relay Contact Output
Standard Configuration One Group AC 250V/2A Normal
Control Method
Power Vector Control
Protect/Alarm Function
Over 20 Kinds Alarm/Protection Fucntion
Cooling Method
Forced Air Cooling
Product Name
UV Lamp Ballast
Trademark
Garle or Neutral
Transport Package
Carton or Wooden Case
Specification
600*220*210mm
Product Description
Water Process Electronic UV Lamp Ballast 1000w Dimming Fan VentilationKey Features:
1. Wide voltage input/output, fit for various UV lamp
1.1. Build-in BUCK voltage stabilizing circuit can be running on AC300-460V;
1.2. The flexible setting output voltage from 200V-500V.
2. Excellent energy saving effect
2.1. Save 30%-50% power consumption comparing with traditional transformer;
2.2. Work efficiency reaches to 98%.
3. Stable output energy, continuous adjustable
3.1. Control system controlled by power vector control algorithm to guarantee output power constantly adjustable;
3.2. Output energy keeps constant when voltage and environment temperature fluctuate.
4. User-friendly
4.1. Intelligent start, auto-detective lamp status, auto-compensation energy descent problem caused by air draft;
4.2. 0~10V voltage continuous control power output;
4.3. Unique standby mode to reduce power consumption and prolong lamp lifetime;
4.4. Visual display output current, voltage, and power. Major loop and control loop wiring terminal are pluggable which convenient for wiring.
5. Abundant protection function
5.1 Nearly 20 kinds of protection function, provide more comprehensive protection on the premise of equipment running normally;
5.2 Receive(PT100, NTC)temperature detective analog quantity signal, real-time monitor lamp temperature and achieve over-temperature protection;
5.3 Receive external equipment malfunction switching value signal, UV power supply immediately alarm to close down the equipment when external equipment breaks down.
6. Integrated frequency conversion draught fan control function
Switch to analog quantity output by SVPWM control algorithm, control draught fan's blast capacity by control frequency converter's output frequency timely to keep lamp voltage and temperature constant to achieve speedy curing effect.
On standby mode by using a unique control algorithm to keep lamp voltage fluctuate in a certain range, lamp response time is 200mS from standby to full power output to achieve speedy response curing requirement.
7. Unique multiple speed power is given by 2 external switching value ON/OFF combination, switch 4 levels adjustable power's preset to achieve different power output switch function. Completely replace traditional transformer+capacitor drive mode.
8. Abundant communication interface
Support Modbus, CANopen, and Ethernet, etc. communication protocol to achieve networking function between multiple power supply, power supply, and other industrial control equipment.
Technical Features:
Input | Nominal voltage, frequency | 3 phase(4T# Series)380V 50/60Hz |
| Voltage allowable range | 3 phase(4T# series)300V~460V |
| Digital input DI | Standard configuration 3 digital input DI1/DI2/DI3 |
| Analog input AI | Standard:0~10V voltage input(AI)or 0~20mA current input(AI) |
Output | Output Voltage | 4T#Series:200-500V |
| Output frequency | 1.0KHz |
| Digital output DO | Standard configuration 3 digital output DO1/DO2/DO3 |
| Analog output AO | 2 route 0.0~10.0V voltage output signal |
| Relay contact output | Standard configuration one group AC 250V/2A normally open/closed contact |
Control method | Power vector control |
Control feature | Power setting resolution | 0.1KW |
| Current Restriction | 110% lamp rated current |
| Voltage Restriction | 110% lamp nominal voltage |
| Power limitation | Max output lamp rated power |
| Overload Capacity | 100%--Long term |
| Under voltage restrain in operation | Especially aim at low network voltage and frequently fluctuate network voltage users, even lower than allowable voltage range, system still maintains its longest conceivable running time by unique algorithm and residual distribution. |
| RS485 Communication | Standard configuration RS485 communication interface, it can control UV power supply running and stop, functional parameter setting and modifying, read equipment status, etc. |
Typical function | Standby function | Set standby power consumption to save energy when the facility is interval. |
| Working time record | Record lamp working time when running |
| Operation function | External dry contact signal, RS485 communication signal control facility start/stop |
Display | Operation panel display | Monitor status | Real-time monitor output power, output current, output voltage, module temperature and setting power. |
| | Alarm content | Latest 6 times malfunction record, every malfunction code, latest malfunction trip output power, setting power, output current, output voltage, DC voltage, module temperature, etc. |
Protect/alarm function | 3 phase current input loss phase, input under-voltage, input over-voltage, output over-current, output short circuit, facility overheat , temperature detection, output disconnection, internal storage damage, etc. |
Environment | Ambient temperature | -10ºC to +45ºC(no freeze) |
| Ambient humidity | 90% below(no frosting) |
| Surroundings | Indoor(NO direct sunlight, corrosion, inflammable gas, oil fog, dust, etc.) |
| Altitude | Lower than 1000m |
Structure | Protection Level | IP20 |
| Cooling method | Forced air cooling |
Model Information:
Model (G3000) | Lamp power(KW) | Input Voltage(V) | Input Current(A) | Output Voltage Range (V) | Max Output Current(A) | Recommended lamp voltage (V) |
4T1003 | 3.0 | 380V AC | 4.6 | 200~500 | 20 | 300 |
4T1004 | 4.0 | 380V AC | 6.1 | 200~500 | 20 | 300 |
4T1005 | 5.0 | 380V AC | 7.6 | 200~500 | 20 | 400 |
4T1006 | 6.0 | 380V AC | 9.3 | 200~500 | 20 | 400 |
4T1008 | 8.0 | 380V AC | 12.3 | 200~500 | 20 | 450 |
4T1010 | 10.0 | 380V AC | 15.1 | 200~500 | 35 | 450 |
4T1012 | 12.0 | 380V AC | 18.2 | 200~500 | 35 | 450 |
4T1015 | 15.0 | 380V AC | 22.8 | 200~500 | 35 | 450 |
Product Detail
G3000 Series UV power supply exterior and installation hole site:
Model (G3000) | Install hole site mm | Exterior size mm | Aperture mm | Screw | Mounting way |
A | B | H | W | D |
4T1003 | 110 | 497 | 520 | 160 | 150 | Φ10 | M8 | Wall-mounted |
4T1004 |
4T1005 |
4T1006 |
4T1008 |
4T1010 | 110 | 497 | 520 | 180 | 178 | Φ10 | M8 | Wall-mounted |
4T1012 |
4T1015 |
UV power supply control loop wiring diagram:
Terminal type | Terminal symbol | Terminal function | Note |
Digital output | DI1 | Programmable multifunctional input terminal Specific function confirmed By P2.01 | Connect CM valid Threshold voltage<16V |
DI2 |
DI3 |
CM | DI reference point | DI,24V common port |
Analog input | AI | Voltage/current signal input end JP2 select voltage or current input | 0~10V voltage input 0~20mA current input |
GND | AI,AO reference point | AI,AO common port |
Analog output | AO1 | Programmable voltage output end 1 Specific mapping variable determined by P2.15 | Voltage signal output 0~10V/1mA |
AO2 | Programmable voltage output end 2 Specific mapping variable determined by P2.15 |
DO output | DO1 | Programmable open collector output Specific function determined by P2.06 | Max load current 150mA Max withstand voltage 24V |
DO2 |
DO3 |
Power output | POW | Provide +24V/100mA power | Auxiliary power supply |
CM | DI,DO output reference point | DI,DO,24V common port |
External power source | 24V | Connect 24V power supply | Use with DO |
External power source | 12V | Connect 12Vpower supply | Use with GND,AI external potentiometer |
485 Communication | RS-,RS+ | R485 communication interface | Connect touch panel, PLC |
Programmable output | TA | normalcy TA-TC break,TA-TB on, specific function determined by P2.06 | Contact capacity:AC 250V/2A |
TB |
TC |
Auxiliary interface | RJ45 | RJ45 interface | Connect external operation panel |
Operation function description:
Items | Function Description |
Display function | First line | Operation panel working mode, display monitor parameter, status parameter and parameter setting |
2nd line | Function code, status parameter and monitor parameter 1 |
3rd line | Parameter function explanation and monitor parameter 2 |
Base line | Power supply working mode and malfunction alarm code |
Keyboard function | ESC | Return key. In normal monitor mode press that key to enter into query model of status parameter, monitor parameter and operation status parameter. In other mode press that key to return to previous level. |
SET | Setting key. Confirm present status or parameter(parameter is stored in internal storage) and enter in next level function menu. |
UP | Data modify increase key to modify function code or status parameter. |
DOWN | Data modify decrease key to modify function code or status parameter. |
>> | Right shift key. In any status which modified by UP and DOWN key press this key to select modifying data bit, modifying position will be flickering. |
<< | Left shift key. In any status which modified by UP and DOWN key press this key to select modifying data bit, modifying position will be flickering. |
Address:
6Floor, Building B4, Yijing Industrial Park, Tianliao Community, Yutang Street, Guangming New District, Shenzhen
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Furniture, Manufacturing & Processing Machinery, Packaging & Printing
Management System Certification:
ISO 9001
Company Introduction:
Shenzhen Garle Electric Technologies Co., Ltd. is a National High-Tech Enterprise and a Software Enterprise recognized by Shenzhen Municipal Science & Technology and Information Bureau. Garle specializes in R&D, production and marketing of intelligent UV variable frequency power supplies, laser power supplies and other inverter power supplies supplied to medium and high end equipment manufacturers.
With expertise based on indigenously developed intellectual property rights, Garle works with customers to quickly provide customers with personalized solutions for development of the company and growth of customer values.
In pursuit of customers′ confidence in our products, Garle deliver superior quality and service to customers, break the monopoly of foreign brands, and provide maximum values for customers at home and abroad, which is the company′s mission.
Following the spirit of innovation and pioneering, Garle employs modern enterprise management practices in creating workflows standardized and efficient internal processes.
The core technology of Garle is creation of products characterized by high efficiency, energy saving, stability, compactness, and light weight through the use of advanced power vector control algorithms in power supply control, high frequency switching power supplies, IGBT inverters and other modern electric and electronic technology. Up to now, Garle has been awarded more than 20 patents, including 1 patent of invention, more than 10 patents of utility models, more than 5 patents for the appearance, and more than 10 software copyrights.
Garle′s products are widely used in printing, painting, woodworking machinery, tinplate printing and other industries.