Basic Info.
Usage
High Intensity Discharge, High Pressure Sodium, UV Lamp Dimming
Matched Tube
Mercury, Metal Halide Lamp, Gallium Lamp or Others
Power Factor Compensation
Active
Certification
CE, RoHS, AAA Certificate
Digital Input
Standard Configuration 3 Digital Input
Digital Output
Standard Configuration 3 Digital Output
Analog Output
2 Route 0.0~10.0V Voltage Output Signal
Relay Contact Output
Standard Configuration One Group AC 250V/2A Normal
Control Method
Power Vector Control
Protect/Alarm Function
Over 20 Kinds Alarm/Protection Fucntion
Cooling Method
Forced Air Cooling
Product Name
Instant Start Ballast
Trademark
Garle or Neutral
Transport Package
Carton or Wooden Case
Specification
600*220*210mm
Product Description
1000 watt dimmable digital ballast for ultraviolet curing lamp
1.Key Features:
Power range: 1.0kW-15kW
Output voltage range:200V-500V
Receiving of fault switch signals from external equipment: when the external equipment fails, the UV viarable frequency power supply immediately sends alarms and stops.
Integrated inverter fan control to ensure appropriate exhaust and improve curing efficiency
Unique multi-stage speed setting, through the combination of the ON/OFF state of two external switches to create four levels of power values to be output
Functions of external terminal start and stop and external stand by to reduce energy consumption and prolong life
Various communication interfaces, including standard RS485 communication interface supporting Modbus RTU, and expansions for CANopen and Ethernet communication.
2.Technical Features:
Input | Nominal voltage, frequency | 3 phase(4T# Series)380V 50/60Hz |
| Voltage allowable range | 3 phase(4T# series)300V~460V |
| Digital input DI | Standard configuration 3 digital input DI1/DI2/DI3 |
| Analog input AI | Standard:0~10V voltage input(AI)or 0~20mA current input(AI) |
Output | Output Voltage | 4T#Series:200-500V |
| Output frequency | 1.0KHz |
| Digital output DO | Standard configuration 3 digital output DO1/DO2/DO3 |
| Analog output AO | 2 route 0.0~10.0V voltage output signal |
| Relay contact output | Standard configuration one group AC 250V/2A normally open/closed contact |
Control method | Power vector control |
Control feature | Power setting resolution | 0.1KW |
| Current Restriction | 110% lamp rated current |
| Voltage Restriction | 110% lamp nominal voltage |
| Power limitation | Max output lamp rated power |
| Overload Capacity | 100%--Long term |
| Under voltage restrain in operation | Specially aim at low network voltage and frequent fluctuate network voltage users, even lower than allowable voltage range, system still maintain its longest conceivable running time by unique algorithm and residual distribution. |
| RS485 Communication | Standard configuration RS485 communication interface, it can control UV power supply running and stop, functional parameter setting and modifying, read equipment status, etc. |
Typical function | Standby function | Set standby power consumption to save energy when facility is interval. |
| Working time record | Record lamp working time when running |
| Operation function | External dry contact signal, RS485 communication signal control facility start/stop |
Display | Operation panel display | Monitor status | Real-time monitor output power, output current, output voltage, module temperature and setting power. |
| | Alarm content | Latest 6 times malfunction record, every malfunction code, latest malfunction trip output power, setting power, output current, output voltage, DC voltage, module temperature, etc. |
Protect/alarm function | 3 phase current input loss phase, input under-voltage, input over-voltage, output over-current, output short circuit, facility overheat , temperature detection, output disconnection, internal storage damage, etc. |
Environment | Ambient temperature | -10ºC to +45ºC(no freeze) |
| Ambient humidity | 90% below(no frosting) |
| Surroundings | Indoor(NO direct sunlight, corrosion, inflammable gas, oil fog, dust, etc.) |
| Altitude | Lower than 1000m |
Structure | Protection Level | IP20 |
| Cooling method | Forced air cooling |
3.Model Information:
Model (G3000) | Lamp power(KW) | Input Voltage(V) | Input Current(A) | Output Voltage Range (V) | Max Output Current(A) | Recommended lamp voltage (V) |
4T1003 | 3.0 | 380V AC | 4.6 | 200~500 | 20 | 300 |
4T1004 | 4.0 | 380V AC | 6.1 | 200~500 | 20 | 300 |
4T1005 | 5.0 | 380V AC | 7.6 | 200~500 | 20 | 400 |
4T1006 | 6.0 | 380V AC | 9.3 | 200~500 | 20 | 400 |
4T1008 | 8.0 | 380V AC | 12.3 | 200~500 | 20 | 450 |
4T1010 | 10.0 | 380V AC | 15.1 | 200~500 | 35 | 450 |
4T1012 | 12.0 | 380V AC | 18.2 | 200~500 | 35 | 450 |
4T1015 | 15.0 | 380V AC | 22.8 | 200~500 | 35 | 450 |
4.Control terminal function description
UV power supply control terminal function description
Terminal type | Terminal symbol | Terminal function | Note |
Digital output | DI1 | Programmable multifunctional input terminal Specific function confirmed By P2.01 | Connect CM valid Threshold voltage<16V |
DI2 |
DI3 |
CM | DI reference point | DI,24V common port |
Analog input | AI | Voltage/current signal input end JP2 select voltage or current input | 0~10V voltage input 0~20mA current input |
GND | AI,AO reference point | AI,AO common port |
Analog output | AO1 | Programmable voltage output end 1 Specific mapping variable determined by P2.15 | Voltage signal output 0~10V/1mA |
AO2 | Programmable voltage output end 2 Specific mapping variable determined by P2.15 |
DO output | DO1 | Programmable open collector output Specific function determined by P2.06 | Max load current 150mA Max withstand voltage 24V |
DO2 |
DO3 |
Power output | POW | Provide +24V/100mA power | Auxiliary power supply |
CM | DI,DO output reference point | DI,DO,24V common port |
External power source | 24V | Connect 24V power supply | Use with DO |
External power source | 12V | Connect 12Vpower supply | Use with GND,AI external potentiometer |
485 Communication | RS-,RS+ | R485 communication interface | Connect touch panel, PLC |
Programmable output | TA | normalcy TA-TC break,TA-TB on, specific function determined by P2.06 | Contact capacity:AC 250V/2A |
TB |
TC |
Auxiliary interface | RJ45 | RJ45 interface | Connect external operation panel |
Address:
6Floor, Building B4, Yijing Industrial Park, Tianliao Community, Yutang Street, Guangming New District, Shenzhen
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Furniture, Manufacturing & Processing Machinery, Packaging & Printing
Management System Certification:
ISO 9001
Company Introduction:
Shenzhen Garle Electric Technologies Co., Ltd. is a National High-Tech Enterprise and a Software Enterprise recognized by Shenzhen Municipal Science & Technology and Information Bureau. Garle specializes in R&D, production and marketing of intelligent UV variable frequency power supplies, laser power supplies and other inverter power supplies supplied to medium and high end equipment manufacturers.
With expertise based on indigenously developed intellectual property rights, Garle works with customers to quickly provide customers with personalized solutions for development of the company and growth of customer values.
In pursuit of customers′ confidence in our products, Garle deliver superior quality and service to customers, break the monopoly of foreign brands, and provide maximum values for customers at home and abroad, which is the company′s mission.
Following the spirit of innovation and pioneering, Garle employs modern enterprise management practices in creating workflows standardized and efficient internal processes.
The core technology of Garle is creation of products characterized by high efficiency, energy saving, stability, compactness, and light weight through the use of advanced power vector control algorithms in power supply control, high frequency switching power supplies, IGBT inverters and other modern electric and electronic technology. Up to now, Garle has been awarded more than 20 patents, including 1 patent of invention, more than 10 patents of utility models, more than 5 patents for the appearance, and more than 10 software copyrights.
Garle′s products are widely used in printing, painting, woodworking machinery, tinplate printing and other industries.